Size 220 mm x 95mm x 45mm
Weight 500g (not including accelerometer)
Environmental Water: MIL-STD-810F, Method 512.4 IP67 sealed against accidental immersion (1m for 30 min) Drop: MIL-STD-810F, Method 516.5, Procedure IV 26 drops from 1.22 m 6 additional drops at –20º 6 additional drops at 60º Operating: -30º to 65º Storage: -40º to 70º Humidity: MIL-STD-810F, Method 507.4 Sand & Dust: IP67, MIL-STD-810F, Method 510.4, Procedures I & II
Power supply Rechargeable battery (charger included)
Battery life Typically 20 hours operating time depending on backlight usage.
Frequency range 10 Hz to 1 kHz (or 15kHz)
Frequency resolution 1.3 Hz (or 18.75 Hz) 800 lines FFT
Displayed Amplitude Units Acceleration in g Velocity in mm/s ( or inches/s)Bearing noise in BDU (bearing damage units)
Displayed Frequency Units Hertz (Hz), RPM or CPM
Input range +/- 50g with standard 25mV/g C-Cubed accelerometer
Dynamic range 120 dB +/- 50g to +/- 0.0004g with standard accelerometer
Auto set up of VA diagnostic bands (RPM = run speed) Instability 10Hz - 0.75 x RPM Unbalance 0.75 x RPM - 1.5 x RPM Alignment 1.5 x RPM - 2.5 x RPM Looseness 2.5 x RPM - 3.5 x RPM
Accelerometer Connection Standard 10 pin IP67 connected smart accelerometer with built-in ID and sensitivity calibration (nominally 25mV/g)
Keypad or Touch screen operation Stylus free collection of vibration data using single key press or touching screen
Options • Carrying case with neck strap • Stylus lanyard • Docking station
|